THAM KHẢO THÔNG SỐ KỸ THUẬT CỦA GĂNG CÁCH ĐIỆN NOVAX

NOVAX  Insulating Gloves  ( EN 60903:2003 )

EN 60903:2003EN6903:20031kV7.5kV17 kV26.5kV36 kV
Class0Class 1Class2: 2YOU-E36YClass 2RC: A POU-Q36YClass3RC: A MOU-Q46Y
Average tensile strength shall be 16MPa16MPa19.7319.4517.0328.424.124.4
Average elongation at break shall be  600% 600%714.8939.5773.9705626412
Average resistance to mechanical puncture shall be greater than 18 N/mm>18 N/mm3148.656.8N/A>51.8>49.4
Thickness ( Dày) mm11.42.32.93.54.2
Tension set shall not exceed 15%< 15%1.251.41.1N/A1.40.8
Electrical requirement

  •  Max. leakage current
  • Max. Withstand test
 

5kV/3min

 

10 kV

 

10kV/3min

 

20 kV

 

20kV/3min

 

30 kV

 

20kV/3min

 

30 kV

 

30kV/3min

 

40 kV

 

40kV/3min

 

50 kV

Ageing requirement After ageing at 70 oC for 168 hour

  • lowest value of tensile strength shall be > 80% of unaged value
  • Tension set shall not exceed 15%

 

  • Gloves shall pass the electrical proof test ( without moisture conditioning )-
> 80%97.9

 

 

2.08

 

3.4mA

(5kV/3min)

97.1

 

 

0.9

 

4.9mA

(10kV/3min)

94.7

 

 

0.7

 

5.9mA

(20kV/3min)

N/A

 

 

N/A

 

.00

N/A

95

 

 

0.8

 

9.3mA

(30kV/3min)

85.4

 

 

1.4

 

8.7mA

(40kV/3min)